ABL-FDB002-6C 4/6 SC Ports FTTH Indoor/Outdoor use Plastic Distribution Box

  • Total enclosed structure.
  • Material: PC+ABS, moisture proof, waterproof, dustproof, anti-aging, protection level up to IP65.
  • Clamping for feeder cable and drop cable, fiber splicing, fixing, storage, distribution, etc. all in one.
  • Cable, pigtails, patch cords run through their own path without disturbing each other, cassette type SC adapter installation, easy maintenance.
  • Distribution panels can be flipped up, feeder cables can be placed in a cup-joint manner, easy to maintain and install.
  • It can be installed wall-mounted or poled-mounted, suitable for both indoor and outdoor use.
  • It supports assembly adapters and micro PLC.

ABL-FDB002 is used as a termination point for the feeder cable to connect with the drop cable in the FTTx communication network system. Fiber splicing, splitting, and distribution can be done in this box, and at the same time it provides solid protection and management for the FTTx network building.

 

Features and Benefits:

  • Total enclosed structure.
  • Material: PC+ABS, moisture proof, waterproof, dustproof, anti-aging, protection level up to IP65.
  • Clamping for feeder cable and drop cable, fiber splicing, fixing, storage, distribution, etc. all in one.
  • Cable, pigtails, patch cords run through their own path without disturbing each other, cassette type SC adapter installation, easy maintenance.
  • Distribution panels can be flipped up, feeder cables can be placed in a cup-joint manner, easy to maintain and install.
  • It can be installed wall-mounted or poled-mounted, suitable for both indoor and outdoor use.
  • It supports assembly adapters and micro PLC.

 

Application

FTTH Indoor/Outdoor use Plastic Distribution Box application
LAN
FTTH Indoor/Outdoor use Plastic Distribution Box application
FTTH
FTTH Indoor/Outdoor use Plastic Distribution Box application
Telecom

Parameter of FTTH Indoor/Outdoor use Plastic Distribution Box

Dimension( L*W*H) 186*116*41mm
Environmental requirement Working temperature:-40℃~+85℃
Relative humidity:≤85% (+30℃)
Atmospheric pressure:70KPa~106Kpa
Main technical datasheet Insertion loss:≤0.2dB
UPC return loss:≥50dB
APC return loss:≥60dB
Life of insertion and extraction:>1000 times
Thunder-proof technical datasheet The grounding device is isolated with the cabinet, isolation resistance is less than 2X104MΩ/500V(DC); IR≥2X104MΩ/500V

The withstand voltage between grounding device and cabinet is no less than 3000V(DC)/min, no punctureno flashover; U≥3000V